    Experimental and analytical performance investigation of air to air two phase closed thermosyphon based heat exchangers

    Get PDF
    In recent years, the use of wickless heat pipes (thermosyphons) in heat exchangers has been on the rise, particularly in gas to gas heat recovery applications due to their reliability and the level of contingency they offer compared to conventional heat exchangers. Recent technological advances in the manufacturing processes and production of gravity assisted heat pipes (thermosyphons) have resulted in significant improvements in both quality and cost of industrial heat pipe heat exchangers. This in turn has broadened the potential for their usage in industrial waste heat recovery applications. In this paper, a tool to predict the performance of an air to air thermosyphon based heat exchanger using the ε-NTU method is explored. This tool allows the predetermination of variables such as the overall heat transfer coefficient, effectiveness, pressure drop and heat exchanger duty according to the flow characteristics and the thermosyphons configuration within the heat exchanger. The new tool's predictions were validated experimentally and a good correlation between the theoretical predictions and the experimental data, was observed. © 2014 Elsevier Ltd. All rights reserved

    Three-dimensional numerical model of heat losses from district heating network pre-insulated pipes buried in the ground

    Get PDF
    The purpose of the paper is to investigate the challenges in modelling the energy losses of heating networks and to analyse the factors that influence them. The verification of the simulation was conducted on a test stand in-situ and based on the measurements of the testing station, a database for the final version of the numerical model was developed and a series of simulations were performed. Examples of the calculated results are shown in the graphs. The paper presents an innovative method of identify the energy losses of underground heating network pipelines and quantify the temperature distribution around them, in transient working conditions. The presented method makes use of numerical models and measured data of actual objects.The dimensions of the pipelines used were 6m wide, 8m high and 1m in depth, while they were simulated under conditions of zero heat flow in the ground, in the perpendicular to the sides direction of the calculated area and considering the effects of ground's thermal conductivity. The mesh was developed using advanced functions, which resulted its high quality with the average orthogonal quality of 0.99 (close to 1.00) and Skewness of 0.05 (between 0.00 and 0.25). To achieve better accuracy of the simulation model, the initial conditions were determined based on the numerical results of a three-dimensional analysis of heat losses, in steady state conditions in a single moment. The validation process confirmed the high quality of the model, as the differences between the ground temperatures were approximately 0.1°C

    Application of steam sootblowers and acoustic generator in power boilers

    No full text
    W artykule przedstawiono negatywny wpływ osadów pyłowych na powierzchniach grzewczych w kotle energetycznym oraz wykazano konieczność utrzymywania ich w czystości. Opisano wybrane sposoby oczyszczania powierzchni konwekcyjnych kotłów z wykorzystaniem zdmuchiwaczy parowych i generatorów akustycznych. Przedstawiono ich budowę, zasadę działania i na podstawie analizy innych badań zaproponowano najlepszy wariant.The adverse influence of contaminated surfaces on boiler's efficiency was described. The necessity of cleaning of heating surfaces in boilers was described. The paper presents the selected cleaning methods, with the application of steam soot blowers and acoustic generators in power boilers. The construction and rule of operation of cleaning devices were presented. Additionally various research was analysed and the best variant was introduced

    Metabolic syndrome is associated with similar long-term prognosis in non-obese and obese patients. An analysis of 45 615 patients from the nationwide LIPIDOGRAM 2004-2015 cohort studies

    No full text
    Aims We aimed to evaluate the association between metabolic syndrome (MetS) and long-term all-cause mortality. Methods The LIPIDOGRAM studies were carried out in the primary care in Poland in 2004, 2006 and 2015. MetS was diagnosed based on the National Cholesterol Education Program, Adult Treatment Panel III (NCEP/ATP III) and Joint Interim Statement (JIS) criteria. The cohort was divided into four groups: non-obese patients without MetS, obese patients without MetS, non-obese patients with MetS and obese patients with MetS. Differences in all-cause mortality was analyzed using Kaplan-Meier and Cox regression analyses. Results 45,615 participants were enrolled (mean age 56.3, standard deviation: 11.8 years; 61.7% female). MetS was diagnosed in 14,202 (31%) by NCEP/ATP III criteria, and 17,216 (37.7%) by JIS criteria. Follow-up was available for 44,620 (97.8%, median duration 15.3 years) patients. MetS was associated with increased mortality risk among the obese (hazard ratio, HR: 1.88 [95% CI, 1.79-1.99] and HR: 1.93 [95% CI 1.82-2.04], according to NCEP/ATP III and JIS criteria, respectively) and non-obese individuals (HR: 2.11 [95% CI 1.85-2.40] and 1.7 [95% CI, 1.56-1.85] according to NCEP/ATP III and JIS criteria respectively). Obese patients without MetS had a higher mortality risk than non-obese patients without MetS (HR: 1.16 [95% CI 1.10-1.23] and HR: 1.22 [95%CI 1.15-1.30], respectively in subgroups with NCEP/ATP III and JIS criteria applied). Conclusions MetS is associated with increased all-cause mortality risk in non-obese and obese patients. In patients without MetS obesity remains significantly associated with mortality. The concept of metabolically healthy obesity should be revised